COMMENTS
There has been a ruling in the high court in London UK where the PCB designer who routed a 0.75mm BGA on a design was made liable for the failure of the product.
An expert claimed that routing the ball stubs all in the same direction caused impedance and that was negligent routing. I would appreciate any comments you all may have as its possible this ruling could have an impact on all of your responsibilities.
Roger Benfield